Para usar en calderas, hornos de panaderia, hornos en general, calentadores de agua, Quemadores Wayne Peru. Quemador a gas Modelo HSG-400. May 17, 2012 hola. Amigos nuevamente con el arranque de un quemador a gas wayne, como pueden ver se realizo un mtto. Preventivo y luego de procedio a su respectivo arranque. • MODELS HSG200 HSG400 A SCOTT FETZER COMPANY GAS BURNERS 801 GLASGOW AVE. FORT WAYNE, IN 46803 120V/50-60 HZ 220V/50 HZ PART NO. 62484-001B US PATENT NO. 4,388,064 WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. • SPECIFICATIONS MODELS HSG200, HSG400 NATURAL OR PROPANE GAS NOTE: Dimensions in ( ) are informational only. English values take priority. HSG200 Maximum Input Capacity - 200 MBtu/HR (211000 kJ) Minimum Input Capacity - 60 MBtu/HR (63300 kJ) HSG400 Maximum Input Capacity - 400 MBtu/HR (422000 kJ) Minimum Input Capacity - 200 MBtu/HR (211000 kJ) SUPPLY LINE PRESSURE REQUIRED: Natural or Propane 5.5 W.C. • Power burner design makes the HSG200 and those required by this burner and that they are in HSG400 well suited for “negative draft” fired proper working order. • Pitch the horizontal run of the flue pipe upward 1/4 inch The draft control should be hood type per Figure 2 or, IF (6.35mm) per foot (.305m) or more. Run directly to the APPROVED BY LOCAL AUTHORITIES, a single chimney, fasten joints securely and support horizontal barometric damper suitable for gas firing per Figure 3. COMBUSTION CHAMBER F. GAS PIPING NOTICE: All piping must comply with state and/or A combustion chamber is normally required to local codes. The available gas supply pressure protect non-heat transfer surfaces, and to provide a should be within minimum and maximum pressures radiant bed for rapid heat transfer to the primary shown in the burner specifications. • AND INSTALLATION The installation must be wired and GROUNDED in accordance with local codes or in their absence, The HSG200 and HSG400 power gas conversion with the National Electric Code ANSI/NFPA No. 70- burners are approved for use with natural and 1987 or latest edition. • COMBINATION GAS VALVE approximately 2.0” W.C. (498.2Pa) to 4.0” W.C. (996.4Pa) is factory set at 3.5” W.C (871.85Pa). The 24 VAC combination gas valve serves three (3) When pressure adjustment is required for setting functions: (1) manual gas shut-off, (2) main gas input capacity with a selected orifice from Figure 10, flame pressure regulator, (3) automatic electric remove the regulator cap for access to the slotted. • SECTION II INITIAL START UP 1. NOTE: Read applicable sequence the primary air damper open or closed to visually burner/primary gas control operation in obtain a blue flame with well defined orange or Section 3 Operation and Troubleshooting yellow tips for natural gas, or well defined yellow tips before proceeding. • CAUTION: IF THE BURNER BTU/HR (kW/Hr) INPUT IS CHANGED, REPEAT STEP 13 the back of this manual or the instruction plate attached to the burner. 3/8” (9.525mm) HSG200 SET AT NO. 1 HSG400 SET AT NO. 1 1/2 Figure 12A Figure 12B IMPORTANT THESE SETTINGS ARE FOR INITIAL STARTUP ONLY, AND MUST BE READJUSTED FOR COMBUSTION EFFICIENCY. • SECTION III OPERATION AND TROUBLESHOOTING SEQUENCE OF OPERATION - HSG SERIES POWER GAS CONVERSION BURNER UTILIZING HONEYWELL S89F GAS PRIMARY P/N 62759-002 W/BUILT IN 30 SECOND PREPURGE On a call for heat, voltage (24V) is applied to motor start the flame rod will provide flame monitoring to the S89F relay and air switch. • SEQUENCE OF OPERATION - HSG SERIES POWER GAS CONVERSION BURNER UTILIZING HONEYWELL S89E GAS PRIMARY P/N 62758-002 W/ EXTERNAL 30 SECOND PREPURGE TIMER P/N 62388-001 AND RESISTOR P/N 62530-001 On a call for heat, voltage (24V) is applied to the motor second prepurge timer and the input terminal to the start relay and air switch. • FLAME SENSING The Honeywell S89 series primary ignition controls through the ionized gas flame to the grounded burner utilize the flame current rectification principal for main head. As the AC current passes through the gas flame, burner flame sensing. It is rectified into a DC current flowing back to the grounded side of the sensing circuit. • The air proving switch is mounted to the housing cover with (2) #6 self tapping screws under the gas HSG200 blower wheel p/n 21664 is positioned valve. A clear plastic tube, protected by a spring 2 1/16” (52.3875mm) measured from the blower cover, is connected to the barbed fitting on the wheel inlet ring face to the side plate face. • DRAWER ASSEMBLY Figure 15 PART NUMBER DIM “A” 21664 HSG200 2 1/16” 5 1/4 O.D. (52.3875mm) (133.35mm) 21642 HSG400 2 3/16” 5 1/2 O.D. (55.5625mm) (139.7mm) MOTOR/BLOWER ASSEMBLY Figure 16 PAGE 16. • Air Cone - (HSG200 only) 21724-011 Adjustable Flange Assembly (includes gasket)(not shown) 100428-002 Flange Gasket (not shown) 21664 Blower Wheel HSG200 5 1/4' OD (133.35mm) 21642 Blower Wheel HSG400 5 1/2' OD (139.7mm) 21658 Side Plate (Used with 20627 and 20627-004 Motors Only) 20627 Motor, Split Phase 1/7 (.107kW) or 1/8 (.093kW) HP 3450 RPM 115V/60. • TECHNICAL INFORMATION “Troubleshooting Guide” NUISANCE LOCKOUTS/FLAME SENSING PROBLEMS - HSG200 & HSG400 GAS BURNERS Wayne’s HSG series direct spark ignition (DSI) gas burner head with approximately 1/16” (1.5875mm) burners prove flame through the process of flame clearance from the head.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. Archives
March 2019
Categories |